Short answer: Most decommissioned data center equipment does not get scrapped. Power and cooling infrastructure — UPS systems, switchgear, transformers, generators, chillers and CRAH units — moves into a secondary market where buyers pay real money for it, because ordering the same equipment new now takes between one and three years. IT hardware follows a separate path governed by data destruction. The value of a decommissioning estate is decided less by age than by capacity, documentation and how the equipment comes out of the building.

Why a secondary market for data center infrastructure exists at all

It exists because of lead times.

A data center cannot energize without switchgear, transformers and standby generation. As of 2026, those are the items that set the schedule. Published 2026 procurement figures put medium-voltage switchgear at 52 to 80 weeks, substation transformers at 75 to 110 weeks, large diesel generators at 90 to 110 weeks, and static UPS systems at 30 to 48 weeks.

Data center equipment lead times in 2026, from order to delivery

Figures per 2026 procurement data.

Read that list as a buyer and the logic is immediate. A two-year-old 1,500 kVA UPS that can be inspected, de-installed and delivered inside a quarter is not competing on price with a new unit. It is competing on time, and time is the scarcer commodity.

This is the single most important thing to understand about this asset class: data center power and cooling equipment holds value because the specification changes slowly and the queue for new units is long. A chiller built in 2019 does the same job as one built in 2026. A 15 kV switchgear lineup does not become obsolete the way a GPU does.

What actually comes out of a decommissioning

Refresh, consolidation and closure release different things, but a full decommissioning typically puts several of these categories on the market at once.

Power and distribution

UPS systems and battery plant, switchgear, transformers, PDUs, busway, automatic transfer switches and distribution panels. The strongest resale category, for the reasons above.

Standby generation

Diesel and gas generator sets, paralleling switchgear, fuel systems, enclosures and controls. Runtime hours matter here more than calendar age — a standby set with low hours and documented load-bank testing is a different asset from one without records.

Cooling and mechanical

Chillers, CRAC and CRAH units, in-row and rear-door cooling, cooling towers, pumps, dry coolers and heat rejection plant. Buyers extend well past data centers into manufacturing, healthcare and institutional facilities.

White space and containment

Racks and cabinets, hot and cold aisle containment, raised flooring, overhead tray and structured cabling. Lower unit values, but it clears quickly and it has to come out regardless.

IT hardware

Servers, storage arrays and network equipment. A separate process entirely — see below.

Life safety and controls

Fire detection and suppression, leak detection, BMS and DCIM controls, environmental monitoring and security systems. Often overlooked in an inventory and frequently still has value.

What determines the value of a decommissioned asset

Six things, roughly in order of weight:

What recovery actually looks like

There is no single number, and anyone quoting one without naming its base is guessing. The most useful anchor is academic rather than promotional.

Research from the National Bureau of Economic Research puts the average liquidation recovery rate for industrial property, plant and equipment at 35% of net book value, with very wide spread by sector — roughly 70% for transportation assets and under 10% in some service industries. For machinery and equipment specifically, the same research reports 32% in aerospace manufacturing, close to the 28% auction-based estimate from earlier work. Lenders price accordingly: a large bank will typically advance 20% to 30% against the book value of industrial PPE.

Source: Kermani and Ma, Asset Specificity of Non-Financial Firms, NBER Working Paper 27642.

What drives that spread is not age. It is specificity and mobility — how many other buyers can use the asset, and how hard it is to move.

Which is the whole argument for data center power and cooling. A 1,500 kVA UPS, a 15 kV switchgear lineup or a 500-ton chiller is not firm-specific: it does the same job in a hospital, a manufacturing plant or another data center. It was designed to be installed, which means it was designed to be removed. And it sits in the one category where new supply is one to three years out. Those are precisely the conditions that place an asset toward the upper end of that distribution rather than the middle of it.

IT hardware is a different problem

Nothing with retained data should enter a sale process. On any live estate, sanitization runs before marketing, not after.

The reference standard is NIST Special Publication 800-88, Guidelines for Media Sanitization, which defines three levels — Clear, Purge and Destroy — and requires verification and documentation of whichever is used. Certified downstream handling is governed by R2v3 and e-Stewards.

In practice this means a documented chain of custody from the rack to the certificate: serialized asset tracking, drive-level records, and a destruction or sanitization certificate that survives audit. On this asset class, chain of custody is part of the value, not an administrative afterthought. An estate that cannot prove what happened to its drives is worth less, because the risk transfers to the buyer.

The building is an asset too

The constraint on new data center development is rarely land. It is power, water, fiber and time.

That is why industrial buildings with existing heavy electrical service, process cooling, water service and heavy floor loading are increasingly marketed to data center developers alongside manufacturers and investors. Incoming service capacity, an existing substation, cooling towers, clear height, column spacing and fiber routes are all expensive to build new and slow to permit.

To be precise about the claim: a building with existing heavy power and cooling is not a data center. It is a shorter route to one than a greenfield site. Whether any specific site suits the use is a question of utility capacity, fiber routing, environmental conditions and local approvals, and it has to be confirmed site by site.

How a decommissioning runs

  1. Assess and document. Inventory the infrastructure, capture specification, capacity, condition and service history, and establish what transfers with the sale and what does not.
  2. Secure the data. Sanitization and documented destruction complete before anything is marketed.
  3. Value against the market. Infrastructure is valued against current lead times and current demand — not against original cost, and not against a depreciation schedule.
  4. Reach the right buyers. Operators, integrators, developers, manufacturers and investors, approached directly.
  5. Transact and clear. Negotiated sale, private treaty or auction, then de-installation, rigging, removal and documented reconciliation.

Common questions

Is decommissioned data center equipment worth anything, or is it scrap?

Power and cooling infrastructure routinely sells well above scrap. Scrap value becomes the floor only when equipment is obsolete by voltage class, damaged, or uneconomic to remove.

What recovery rate should I expect on decommissioned equipment?

Across industrial plant and equipment generally, NBER research puts the average liquidation recovery at 35% of net book value, ranging from roughly 70% down to under 10% depending on sector. Where a given asset lands depends mainly on how specific it is to one user and how easily it moves. Data center power and cooling scores well on both counts, and faces unusually long replacement lead times, which supports recovery above a generic industrial average.

Does age determine the value of data center equipment?

Less than people expect. Capacity, condition, documentation and removal access matter more. Electrical and mechanical specifications change slowly.

What is the difference between ITAD and asset disposition?

ITAD generally covers IT hardware and the data security chain around it. Asset disposition covers the whole estate — power, cooling, white space, life safety and the building itself.

When should a data center decommissioning start?

Before the equipment is switched off, where possible. Equipment that can be inspected running, with records intact, recovers more than equipment already disconnected and stacked on a loading dock.

What happens to UPS batteries during a decommissioning?

They are handled separately under hazardous material rules and rarely travel with the UPS. Battery condition and replacement date should be documented regardless.

AssetBuilt handles data center asset disposition on both sides of this market: infrastructure out of refresh, consolidation and closure programmes, and industrial sites brought to developers. The firm has monetized $10B+ in assets globally, with 2.7M+ active bidders and 200+ years of combined team experience.